DVS
filters are certified carbon-carbon NucFil® HEPA drum vent filters
that meet WIPP WAC and TRUPACT-II SAR Appendix 1.3.5 requirements: |
| |
|
|
|
H2
permeability exceeds 5 E-06 mol/s/mol fraction |
| |
|
|
|
Greater
than 99.97% removal of 0.45 micron DOP |
| |
|
|
|
Greater
than 200 ml/min air flow capacity at < 1.0" W.C. |
|
|
|
|
The
DVS filter design passes the DOT 7A drop test, stacking test, vibrations
test, dart impact and water entry test. |
|
| |
|
Drum
Vent and Purge Filters |
|
|
|
The
NucFil®-049 LS penetrates an 85-gallon over pack, 55-gallon drum
and a 90-mil liner. |
|
|
|
|
The
NucFil®-072 was used to vent over 30,000 drums at the Savannah
River Site. |
|
|
|
|
The
NucFil®-DVS3 is designed to allow the maximum hydrogen diffusion
through a 90-mil liner and drum lid. |
|
|
|
|
The
NucFil®-049 S is installed if a longer stem DVS filter is stopped
by an impenetrable object. |
| |
|
|
|
|
|

IN
THE FIELD
The figure to the left is a radiograph of a NucFil®-072 in a
55-gallon drum of TRU waste at the Nevada Test Site. Radiography
verifies filter penetration of the 90-mil liner inside the 55-gallon
drum.
|