Nuclear
Filter Technology's NucFil®-019 HCR highly corrosion resistant
drum vent filter is engineered to provide the same hydrogen diffusivity
as our original NucFil®-019 design, plus provide excellent chloride
and acid corrosion resistance. |
|
|
|
|
Filters
are certified carbon-carbon HEPA drum vent filters that meet WIPP
WAC and TRUPACT-II SAR Appendix 1.3.5 requirements: |
| |
|
|
|
H2
permeability exceeds 20 E-06 mol/s/mol fraction- a 5X filter |
| |
|
|
|
Greater
than 99.97% removal of 0.45 micron DOP |
|
|
|
|
|
Greater
than 200 ml/min air flow capacity at <1.0" W.C. |
|
|
|
|
The
carbon-carbon composite filter media: |
| |
|
|
|
Resists
acid and chloride corrosion |
| |
|
|
|
Is
70% porous |
| |
|
|
|
Is
unaffected by extreme temperatures. |
|
|
|
|
|
Chemical
resistance testing conducted in Nuclear Filter Technology's R&D
Laboratory: |
|
| |
|
|
|
Tested
in 1 liter desiccators with 12 molar (concentrated) hydrochloric acid
(HCI) vapors. |
|
| |
|
|
|
Accelerated
tests: |
|
| |
|
|
|
|
|
Vapor
Pressure of 12 molar HCI at room temperature produces a vapor concentration
of about 100,000 ppmv of HCI |
|
| |
|
|
|
|
|
HCI
concentration in desiccators kept constant; not decreasing concentration
over time |
|
| |
|
|
|
|
|
Worst
case expected in TRU waste drums is a vapor concentration of about
30 ppmv of HCI |
|
| |
|
|
|
|
|
Accelerated
test by more than 3,000 times expected challenge (HCI concentration) |
|
| |
|
|
|
|
|
100%
immersion of filter sample in vapor, not just one side in vapor and
the other in cleaner air. |
|